NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays

MPN AS-2015CS-TNR
2U CloudDC with 12 hot-swap 3.5" NVMe/SAS/SATA bays and 4 PCIe 5.0 x16 slots + 2 AIOM slots

Key capabilities

  • Single AMD EPYC™ 9004/9005* Series Processor (*AMD EPYC™ 9005 series drop-in support requires board revision 2.x)
  • Support up to DDR5 12 DIMM slots (1DPC)
  • 2 PCIe 5.0 x16 FHFL + 2 PCIe 5.0 x16 FHHL + 2 PCIe 5.0 x8 FHFL(Optional)
  • Dual AIOM (OCP 3.0) for networking, 1 dedicated IPMI LAN
  • 12 Hot-swap 3.5"/2.5" SATA drive bays
Part#: CMDA001U12


Product
NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays
Part number
AS-2015CS-TNR
Category
Services › Rack Integration
Form factor
2U rackmount
Typical workloads
virtualization, private cloud, and enterprise applications
Configuration
Engineer-to-order via Configure (CPU, memory, GPU, storage, networking).
Vendor
RackmountNTS (New Tech Solutions, Inc.), Fremont, California, USA.
Facility
ISO-aligned staging, imaging, and burn-in at NTS HQ in Fremont, CA.

NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays


Enterprise 2U Rack Server — Engineer-to-Order Configuration


The NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays is configured engineer-to-order by New Tech Solutions (RackMountNTS) for enterprise infrastructure, data-center deployments, and storage-intensive computing environments. Its 2U rackmount form factor and 12 hot-swap drive bays provide a platform for building server configurations around application requirements, storage capacity, and data availability needs.
Use Configure to select compatible processor, memory, storage, and networking options available for the platform. NTS reviews the proposed bill of materials (BOM), component compatibility, power requirements, thermal constraints, firmware, and driver readiness before shipment. Systems undergo staging and validation at the NTS facility in Fremont, California.

Storage Flexibility and Data-Center Integration


The 12 hot-swap drive-bay design supports storage configurations suited to workloads that require flexible drive servicing and capacity planning. Depending on the selected configuration and supported components, the server can be specified for enterprise data storage, application hosting, virtualization, and data-center infrastructure.
NTS helps align processor selection, memory capacity, storage devices, drive interfaces, and network connectivity with the intended workload. Final drive compatibility, storage-controller requirements, supported drive types, and maximum capacity should be confirmed for the selected system configuration.

Validated Configuration and Deployment Readiness


Each configurable system follows an engineering-led process designed to reduce component compatibility issues before deployment. NTS reviews the selected hardware configuration, verifies applicable power and cooling requirements, and prepares firmware, drivers, and system documentation for handoff.
Commercial customers receive configuration review, component validation, serial-tracked acceptance processes, and lifecycle support options. Federal, defense, and state, local, and education (SLED) customers can also discuss procurement requirements and bill-of-material alignment for applicable contract vehicles, including SEWP V, ITES-4H, and GSA MAS, subject to contract scope and solicitation requirements.

Configure Your 2U Server


Use the Configure workbench to review available system options and build a configuration around your processor, memory, storage, and networking requirements. Where supported by the platform and selected components, NTS can help evaluate interface compatibility, rack power budgets, deployment constraints, and expected workloads.
After selecting options, review the displayed configuration and pricing. Submit a Request a Quote to receive a proposal with applicable lead times, configuration details, and sourcing notes where required. Gold SKUs may be offered as fixed configurations, while designated configurable SKUs follow the engineer-to-order process.

Engineering Support and Procurement Assistance


For configuration assistance, share your intended workload, target CPU and memory requirements, storage capacity, network interfaces, rack power budget, and delivery schedule with an NTS specialist through Contact NTS or Request a Quote.
Explore related resources:
From individual server deployments to larger infrastructure rollouts, RackMountNTS supports configuration planning, hardware validation, deployment preparation, and procurement coordination to help customers move from system requirements to a deployment-ready server.

Product overview

Highlights and workloads for NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays.

Overview

2U CloudDC with 12 hot-swap 3.5" NVMe/SAS/SATA bays and 4 PCIe 5.0 x16 slots + 2 AIOM slots
Form Factor2U Rackmount
Enclosure437 x 89 x 648mm (17.2" x 3.5" x 25.5")
Package679 x 296 x 876mm (26.7" x 11.4" x 34.5")
ProcessorSingle processor(s)
AMD EPYC™ 9004/9005 Series Processors
(* AMD EPYC™ 9005 Series drop-in support requires board revision 2.x)
Up to 160C/320T
GPUMax GPU Count: Up to 2 double-width or 4 single-width GPUs
Supported GPU: NVIDIA PCIe: A100, A16, A2, A30, A40, L4, L40, L40S, RTX 6000 Ada Generation, RTX A4000
CPU-GPU Interconnect: PCIe 5.0 x16 CPU-to-GPU Interconnect
GPU-GPU Interconnect: PCIe
System MemorySlot Count: 12 DIMM slots
Max Memory (1DPC): Up to 3TB 4800MT/s ECC DDR5 RDIMM (AMD EPYC™ 9004 Series Processor, MB
R1.x/R2.0/R2.01)
Max Memory (1DPC): Up to 3TB 6000MT/s ECC DDR5 RDIMM (AMD EPYC™ 9005 Series Processor, MB R2.0)
Max Memory (1DPC): Up to 3TB 6400MT/s ECC DDR5 RDIMM (AMD EPYC™ 9005 Series Processor, MB R2.01)
Drive BaysConfiguration Default: Total 12 bays
12 front hot-swap 3.5"/2.5" SATA drive bays
Option A: Total 4 bays
4 front hot-swap 2.5" PCIe 5.0 NVMe* drive bays
Option B: Total 12 bays
12 front hot-swap 3.5"/2.5" SAS* drive bays
(*NVMe/SAS support may require additional storage controller and/or cables, please see the optional parts list for
details)
M.2: 2 M.2 PCIe 3.0 x2 NVMe slots (M-key 2280/22110)
Expansion SlotsDefault
2 PCIe 5.0 x16 FHFL slots
2 PCIe 5.0 x16 FHHL slots
2 PCIe 5.0 x16 AIOM slots (OCP 3.0 compatible)
Option A*
2 PCIe 5.0 x8 FHFL slots
On-Board DevicesVia AIOM
Input / OutputLAN: 1 RJ45 1 GbE Dedicated BMC LAN port
USB: 2 USB 3.0 ports (rear)
Video: 1 VGA port
Serial: 1 COM port (rear)
TPM: 1 TPM header
System CoolingFans: Up to 3x 8cm heavy duty fans with optimal fan speed control
Air Shroud: 1 Air Shroud
Power Supply2x 1200W Redundant (1 + 1) Titanium Level (96%) power supplies
System BIOSBIOS Type: AMI 32MB SPI Flash ROM
BIOS Features: ACPI 6.4
Plug and Play (PnP)
SMBIOS 3.5 or later
UEFI 2.8
USB Keyboard support
ManagementSuperCloud Composer® (SCC); Supermicro Server Manager (SSM); Supermicro Update Manager (SUM);
Supermicro SuperDoctor® 5 (SD5); Super Diagnostics Offline (SDO); Supermicro Thin-Agent Service (TAS); OOB
Management Package (SFT-OOB-LIC ); SuperServer Automation Assistant (SAA) New!
PC Health MonitoringFan: Fans with tachometer monitoring
Pulse Width Modulated (PWM) fan connectors
Status monitor for speed control
Temperature: Monitoring for CPU and chassis environment
Thermal Control for fan connectors
Voltage:
System temperature, Memory temperature, CPU temperature, 3.3V standby, +5V standby, +5V, +3.3V, +12V, CPU
thermal trip support
Dimensions and WeightWeight: Gross Weight: 59 lbs (26.76 kg)
Net Weight: 33 lbs (15 kg)
Available Color: Black front & sliver body
Operating EnvironmentOperating Temperature: 10°C to 35°C (50°F to 95°F)
Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
MotherboardSuper H13SSW
ChassisCSE-LA26TS-R1K23AWP1

Build Your Configuration

Processors · memory · storage · networking · power
Select options below — pricing updates in real time as you configure.
  • Real-time pricing
  • SEWP V · ITES-4H quoting
  • U.S. integration & burn-in

Expand each group below to choose options — required fields are marked. Selections update pricing in real time.

Barebone
Processor
Memory
M.2 DRIVE
(Max Quantity: 2)
HARD DRIVE
(Max Quantity: 12)
GPU
(Max Quantity: 4)
CONTROLLER CARD
Battery Backup
NETWORK ADAPTER
(Max Quantity: 3)
Trusted Platform Module
Power Cables
SERVER MANAGEMENT
I O Modules Networking
OPERATING SYSTEM
NTS AI Stack See what's inside each NTS AI package
Software
NVIDIA Software
Warranty

Why teams choose NTS

Engineer-to-order platforms with U.S. integration, federal contract paths, and workload-aware BOM review — not catalog-only SKUs.

Enterprise rack servers configured for U.S. integration and delivery

Built in the USA

Configuration, burn-in, and rack staging from Fremont, California with nationwide delivery.

Contract-native quoting

ITES-4H, SEWP V, and OMNIA Partners paths with CLIN-ready BOM structure.

Engineer-to-order

Choose CPU, memory, pcie expansion, storage, network, and redundant power per workload.

Rack-ready delivery

Serial capture for CMDB, integration validation, and specialist turn-up support.

Solutions & Deployment

Optimized reference architectures, workload deployment patterns, and technical specifications for the NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays

Platform at a Glance

2U server chassis staged for factory burn-in and rack-ready deployment

2U Chassis

Custom engineer-to-order 2u chassis featuring rigorous factory burn-in, thermal validation, and seamless rack-ready deployment.
Enterprise server PCIe expansion with NICs, HBAs, and accelerator cards

Enterprise Expansion

High-bandwidth PCIe Gen 4/5 expansion slots supporting high-speed NICs, SAS/SATA/NVMe HBAs, and dedicated hardware accelerators.
U.S. integration facility validating server systems for federal and SLED programs

U.S. Integration

Secure U.S.-based configuration, multi-point validation, and compliant logistics tailored for federal, defense, and SLED programs.
Procurement specialist preparing federal and SLED contract quotes

Contract Quoting

Streamlined procurement via ITES-4H, NASA SEWP V, and SLED cooperative contracts with pre-negotiated pricing.

Delivery & Integration Lifecycle

From initial BOM design to production-ready deployment, our dedicated engineering team manages the complete lifecycle of your NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays.
NTS engineers staging server racks with structured cabling before datacenter deployment
  • Build & Burn-In
    Precision factory assembly, custom firmware baselining, rigorous stress testing, and comprehensive asset documentation prior to shipment.
  • Rack Integration
    Structured cabling, optimized power distribution, and comprehensive in-rack validation aligned with your specific data center standards.
  • Image & Tag
    Custom OS/hypervisor imaging, host-name provisioning, and automated serial/asset tag capture for seamless CMDB and ITAM integration.
  • Deliver & Support
    Secure, coordinated logistics combined with post-delivery engineering support to ensure rapid, hassle-free site turn-up.
Enterprise server architecture with compute, storage, and expansion tiers

System Architecture

NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays is a high-density, storage-optimized platform engineered for sustained I/O throughput, front-serviceable hot-swap drive bays, and seamless capacity scaling without disruptive forklift upgrades.
  • Right-size CPU, memory, and I/O in an engineer-to-order BOM — validated and burn-tested in Fremont before ship
  • Add NICs, HBAs, and accelerators through PCIe expansion without chassis constraints
  • Scale east-west and cluster traffic on 10/25/100GbE-class networking without platform upgrades
  • Match storage latency to workload — NVMe, SAS, or SATA tiers in the same chassis
  • Keep mission workloads online with redundant power and cooling for 24×7 operation
  • Image, monitor, and troubleshoot remotely from day one via IPMI / BMC
Federal procurement specialist reviewing contract compliance documentation alongside secure server integration

Procurement & Compliance

Procure NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays through SEWP V, ITES-4H, and SLED cooperative contracts. Benefit from CLIN-ready BOM structures, full compliance documentation, and secure delivery coordinated by our Fremont integration specialists.
  • Acquire federal, DoD, and public-sector quotes precisely mapped to your contract CLINs, funding cycles, and periods of performance
  • Access complete Trade Agreements Act (TAA) compliance and country-of-origin documentation for seamless contracting officer approval
  • Streamline agency acquisition reviews with detailed Energy Star ratings and power-efficiency metrics
  • Maintain strict property accountability with pre-captured serial numbers, MAC addresses, and custom asset tags for audit-ready tracking
  • Ensure compliance with FIPS 140-3 and NIST SP 800-53 security standards through pre-award engineering consultations
  • Coordinate secure, scheduled delivery windows directly with your ACO or COR, arriving fully integrated and rack-ready
SEWP V ITES-4H SLED Cooperatives CLIN-ready BOM Fremont, CA
Contract vehicles for this SKU are listed under Available through next to the product image. Explore SEWP V, ITES-4H, GSA, and SLED procurement paths →

Ideal Use Cases

Enterprise deployment scenarios where NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays delivers optimal price-performance, high reliability, and simplified serviceability.
Enterprise virtualization on NTS rack servers with brand plaque

Virtualization

Consolidate VMs with predictable CPU and I/O headroom.
Enterprise application hosting on NTS dual-socket servers

Enterprise Applications

Run ERP, databases, and line-of-business stacks.
Compact NTS systems for edge and ROBO deployments

Edge & ROBO

Deploy closer to users with a compact rack footprint.
Research computing clusters built on NTS platforms

Research Computing

Support engineering and scientific simulation tiers.
Private cloud IaaS tiers on NTS engineer-to-order servers

Private Cloud

On-prem IaaS with configurable compute and storage.
VDI session hosts on NTS rack and tower platforms

VDI

Session density with balanced CPU, GPU, and storage.

Common workload profiles

Typical deployment patterns aligned to NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays capacity, I/O profile, and service tiers.
VMware and Hyper-V virtualization workloads

VMware / Hyper-V

Consolidated VMs with shared datastore headroom.
SQL and Oracle database hosting workloads

SQL & Oracle

Low-latency volumes for transactional databases.
Web and application tier hosting workloads

Web & app tiers

Horizontal scale for stateless application pools.
Centralized file services and shared storage

File services

Centralized SMB/NFS shares with tiered capacity.
Monitoring, metrics, and log ingest workloads

Monitoring stacks

Time-series and log ingest with retention policies.
Development and test lab infrastructure workloads

Dev/test labs

Isolated environments with snapshot-friendly volumes.

Frequently Asked Questions

Common technical and procurement topics for NTS Elite Command 2U Server with 12 Hot-Swap Drive Bays. Additional questions are handled by our specialists and knowledge base.

Need architecture guidance or a formal quote?

Service & Trust

Coverage, procurement, and domain expertise for Rack Integration platforms — backed by U.S. integration and contract-native quoting.
  • NTS Fremont integration floor — rack staging and burn-in with NTS branding on the rack
    Built & Supported in the USA Factory-aligned configuration, validation, burn-in, and rack integration from Fremont, CA — with nationwide logistics for federal and commercial programs.
  • Nationwide U.S. logistics and data center delivery support with NTS-branded equipment crates
    Nationwide Coverage Delivery and post-sales engineering across all U.S. regions — defense, civilian agency, higher education, and commercial data center.
  • Contract-native quoting workstation with CLIN-aligned BOMs beside an NTS-branded secure server
    Contract-Native Quoting CLIN-aligned BOMs for ITES-4H, SEWP V, and SLED cooperative vehicles — view all contract paths.
  • NTS solution architects consulting on an AI and HPC rack with NTS branding on the chassis
    Rack Integration Expertise Dedicated solution architects for AI, HPC, virtualization, storage, and edge — from first quote through rack turn-up.